whereby till communicate DTC1000 via DVP 14 ss ( Delta PLC)

just connect triangle PLC and solid DTC semiconductor through RS485 port and download of program(in pdf) as i have fixed it in previous post.
 
Why adding 400001

Hi,
I've connected DTC1000 to a FATEK PLC real I want to read the measured temperature and writes it in R2000 for sample


A companion said read this file
http://www.deltaww.com/filecenter/P...405/Manual/DELTA_IA-TC_DTC_OM_EN_20160311.pdf


So I saw that the value will go to 1000H which is 4096 in Decimal
But that didn't worked and my friend says you should add 400001 to it. It means that PLC desktop can reader data at 404097 additionally it WORKED. I'd same to know where save has number komm from or maybe I'm making mistakes to my understandings



Thanks
 